Akan lebih mudah bagi Anda untuk mencari kolom HPLC yang cocok dengan memulainya dari jenis sampel yang digunakan.
Sample | Category | Separation Mode | Recommended Column | Page | Remark |
Low-MW drugs |
- |
Reversed phase | C18-EB | 30 | Near-perfect end capping treatment |
COSMOCORE C18 | 32 | ||||
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Normal phase | SL-II | 42 | Standard for normal phase | ||
Vitamins |
Water-soluble vitamins |
Reversed phase | C18-PAQ | 28 | Compatible with 100% water based mobile phase |
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Fat-soluble vitamins | Reversed phase | C18-MS-II | 24 | Standard for reversed phase | |
Cholester | 10 | Different selectivity from C18 | |||
Normal phase | SL-II | 42 | Standard for normal phase | ||
Natural products |
- |
Reversed phase |
C18-MS-II | 24 | Utilize various interactions for versatile separations. See each product page for details. |
Cholester | 10 | ||||
PBr | 14 | ||||
πNAP | 18 | ||||
Normal phase | SL-II | 42 | Suitable for preparative separation | ||
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Organic acids |
- |
Reversed phase | C18-PAQ | 28 | Compatible with 100% water based mobile phase |
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Fatty acids | - | Reversed phase | C18-AR-II | 26 | Features strong acid resistance |
Cholester | 10 | Different selectivity from C18 | |||
Phospholipids | Molecular species | Reversed phase | C18-MS-II | 24 | Standard for reversed phase |
Class species | Normal phase | SL-II | 42 | Standard for normal phase | |
Agricultural chemicals |
- |
Reversed phase | C18-MS-II | 24 | Standard for reversed phase |
Cholester | 10 | Different selectivity from C18 | |||
Normal phase | SL-II | 42 | Standard for normal phase | ||
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Metabolites |
- |
Reversed phase | C18-MS-II | 24 | Standard for reversed phase |
Cholester | 10 | Different selectivity from C18 | |||
Normal phase | SL-II | 42 | Standard for normal phase | ||
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Food additives |
- |
Reversed phase | C18-MS-II | 24 | Standard for reversed phase |
Cholester | 10 | Different selectivity from C18 | |||
Normal phase | SL-II | 42 | Standard for normal phase | ||
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Other low-MW compounds |
- |
Reversed phase | C18-MS-II | 24 | Standard for reversed phase |
Cholester | 10 | Different selectivity from C18 | |||
Normal phase | SL-II | 42 | Standard for normal phase | ||
Hydrophilic interaction | HILIC | 44 | Retains highly polar compounds that would not be retained in C18 column | ||
Structural isomers Structural analogs |
- |
Reversed phase |
C18-MS-II | 24 |
Utilize various interactions for versatile separations. See each product page for details. |
C18-AR-II | 26 | ||||
Cholester | 10 | ||||
πNAP | 18 | ||||
PYE | 20 | ||||
NPE | 22 | ||||
PBr | 14 | ||||
PFP | 17 | ||||
Normal phase | SL-II | 42 | Standard for normal phase |
Masih belum menemukan yang Anda cari? Tanya kepada staf kami WA. +62 812-9318-5185
Download Katalog Lengkap Kolom HPLC Cosmosil merk Nacalai Tahun 2023